bsen934-2-2001-20xxadmixturesforconcretemortarandgrout内容摘要:
y of admixtures for concrete . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 CE marking and labelling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Table Table 1 – General Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Table 2 – Specific requirements for water reducing/plasticizing admixtures (at equal consistence) . . . . . . . . . . . 10 Table – Specific requirements for high range water reducing/super plasticizing admixtures (at equal consistence) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Table – Specific requirements for high range water reducing/super plasticizing admixtures (at equal w/c ratio) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Table 4 – Specific requirements for water retaining admixtures (at equal consistence) . . . . . . . . . . . . . . . . . . 11 Table 5 – Specific requirements for air entraining admixtures (at equal consistence) . . . . . . . . . . . . . . . . . . . 11 Table 6 – Specific requirements for set accelerating admixtures (at equal consistence) . . . . . . . . . . . . . . . . . 11 Table 7 – Specific requirements for hardening accelerating admixtures (at equal consistence) . . . . . . . . . . . . 12 Table 8 – Specific requirements for set retarding admixtures (at equal consistence) . . . . . . . . . . . . . . . . . . . . 12 Table 9 – Specific requirements for water resisting admixtures (at equal consistence or equal w/c ratio . . . . . . 12 Table 10 – Specific requirements for set retarding/water reducing/plasticizing admixtures (at equal consistence) 13 Table – Specific requirements for set retarding/high range water reducing/ superplasticizing admixtures (at equal consistence) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Table – Specific requirements for set retarding/high range water reducing/ superplasticizing admixtures (at equal w/c ratio) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Table 12 – Specific requirements for set accelerating/water reducing/plasticizing admixtures (at equal consistence) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 13 – Minimum frequency of test for the factory production control of concrete admixtures according to EN 9342 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Table – Scope and relevant clauses of this standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Table – System of attestation of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Table – Assignation of evaluation of conformity tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 EN 9342:2020 (E) 3 Foreword This European Standard has been prepared by Technical Committee CEN/TC 104 Concrete, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2020, and conflicting national standards shall be withdrawn at the latest by April 2020. This European Standard supersedes EN 9342:1997. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s) see informative annex ZA which is an integral part of this standard. This standard is a part of the series EN 934 Admixtures for concrete, mortar and grout which additionally prises the following parts Part 3 Admixtures for masonry mortar Definitions, requirements, conformity, marking and labelling Part 4 Admixtures for grout for prestressing tendons Definitions, requirements, conformity, marking and labelling Part 5 Admixtures for sprayed concrete Definitions, requirements, conformity, marking and labelling Part 6 Sampling, conformity control and evaluation of conformity This European Standard is used with the standards of the EN 480 series which prises test methods for admixtures. The annexes A and ZA are informative. According to the CEN/CENELEC Internal Regulations, the national standards anizations of the fo llowing countries are bound to imp lement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. Foreword to amendment A1 This document (EN 9342:2020/A1:2020) has been prepared by Technical Committee CEN/TC 104 “Concrete and related products”, the secretariat of which is held by DIN. This Amendment to the European Standard EN 9342:2020 shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2020, and conflicting national standards shall be withdrawn at the latest by April 2020. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s).。bsen934-2-2001-20xxadmixturesforconcretemortarandgrout
阅读剩余 0%
本站所有文章资讯、展示的图片素材等内容均为注册用户上传(部分报媒/平媒内容转载自网络合作媒体),仅供学习参考。
用户通过本站上传、发布的任何内容的知识产权归属用户或原始著作权人所有。如有侵犯您的版权,请联系我们反馈本站将在三个工作日内改正。